{"id":10991,"date":"2024-11-18T15:44:51","date_gmt":"2024-11-18T15:44:51","guid":{"rendered":"https:\/\/appliedfloors.com\/?p=10991"},"modified":"2024-11-18T15:44:51","modified_gmt":"2024-11-18T15:44:51","slug":"temperature-point-de-rosee-et-conditions-environnementales-dans-les-installations-de-revetements-de-sol-en-resine","status":"publish","type":"post","link":"https:\/\/appliedex.com\/fr\/blog\/temperature-dew-point-and-environmental-conditions-in-resinous-flooring-installations\/","title":{"rendered":"Temp\u00e9rature, Point de Ros\u00e9e et Conditions Environnementales dans les Installations de Rev\u00eatements de Sol R\u00e9sineux"},"content":{"rendered":"<h2 class=\"wp-block-heading\" id=\"ember880\">L'importance des conditions environnementales dans les installations de rev\u00eatements de sol r\u00e9sineux \ud83c\udf21\ufe0f\ud83d\udca7<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"ember881\">Contr\u00f4le appropri\u00e9 de <strong>temp\u00e9rature<\/strong>, <strong>point de ros\u00e9e<\/strong>, et <strong>conditions environnementales<\/strong> est essentiel pour l'installation r\u00e9ussie de rev\u00eatements \u00e9poxydes, de ciment polyur\u00e9thane, de polyaspartique et de syst\u00e8mes de planchers MMA. Une mauvaise gestion peut entra\u00eener des d\u00e9faillances telles qu'une mauvaise adh\u00e9rence, des bulles ou un durcissement incoh\u00e9rent. Dans ce guide, nous aborderons :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Comment mesurer la temp\u00e9rature du b\u00e9ton et de l'air<\/li>\n\n\n\n<li>Diff\u00e9rences dans les syst\u00e8mes de rev\u00eatement de sol et leurs besoins environnementaux<\/li>\n\n\n\n<li>L'impact des syst\u00e8mes CA et CVC sur l'installation<\/li>\n\n\n\n<li>Meilleures pratiques pour maintenir des conditions id\u00e9ales<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"ember883\">Mesure de la temp\u00e9rature du b\u00e9ton et de l'air<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"ember884\">Mesure pr\u00e9cise de <strong>substrat<\/strong> et <strong>temp\u00e9ratures de l'air<\/strong> est crucial car ces facteurs ont un impact direct sur l\u2019adh\u00e9rence, la polym\u00e9risation et la long\u00e9vit\u00e9 des syst\u00e8mes de rev\u00eatement de sol r\u00e9sineux.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"ember885\">Comment mesurer la temp\u00e9rature du b\u00e9ton<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Utilisez un thermom\u00e8tre infrarouge<\/strong><\/li>\n\n\n\n<li><strong>Utilisez un thermom\u00e8tre de surface ou une sonde<\/strong><\/li>\n\n\n\n<li><strong>Pr\u00e9parer la surface<\/strong><\/li>\n\n\n\n<li><strong>Surveiller plusieurs points<\/strong><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"ember887\"><strong>Astuce cl\u00e9 :<\/strong> Assurez-vous que le b\u00e9ton s'acclimate \u00e0 l'environnement pendant au moins <strong>24-48 heures<\/strong> avant l'installation.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"745\" height=\"418\" src=\"https:\/\/appliedex.com\/wp-content\/uploads\/2024\/11\/1731812367701.jpg\" alt=\"Mesure de la temp\u00e9rature avec un thermom\u00e8tre infrarouge\" class=\"wp-image-10995\" srcset=\"https:\/\/appliedex.com\/wp-content\/uploads\/2024\/11\/1731812367701.jpg 745w, https:\/\/appliedex.com\/wp-content\/uploads\/2024\/11\/1731812367701-300x168.jpg 300w, https:\/\/appliedex.com\/wp-content\/uploads\/2024\/11\/1731812367701-18x10.jpg 18w\" sizes=\"(max-width: 745px) 100vw, 745px\" \/><figcaption class=\"wp-element-caption\">Mesure de la temp\u00e9rature avec un thermom\u00e8tre infrarouge <\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"ember889\">Comment mesurer la temp\u00e9rature de l'air<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Utilisez un hygrom\u00e8tre ou un thermom\u00e8tre num\u00e9rique<\/strong><\/li>\n\n\n\n<li><strong>\u00c9viter les sources de chaleur ou de froid directes<\/strong><\/li>\n\n\n\n<li><strong>Mesurer r\u00e9guli\u00e8rement<\/strong><\/li>\n\n\n\n<li><strong>Surveiller l'humidit\u00e9 relative (HR)<\/strong><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"ember891\"><strong>Astuce cl\u00e9 :<\/strong> Enregistrez les relev\u00e9s pour vous assurer que les conditions sont conformes aux sp\u00e9cifications du fabricant.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"ember892\">Temp\u00e9rature du b\u00e9ton vs. Temp\u00e9rature de l'air : Principales diff\u00e9rences<\/h3>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"388\" src=\"https:\/\/appliedex.com\/wp-content\/uploads\/2024\/11\/1731810850438-1024x388.png\" alt=\"Graphique de la temp\u00e9rature du b\u00e9ton et de l&#039;air\" class=\"wp-image-11001\" srcset=\"https:\/\/appliedex.com\/wp-content\/uploads\/2024\/11\/1731810850438-1024x388.png 1024w, https:\/\/appliedex.com\/wp-content\/uploads\/2024\/11\/1731810850438-300x114.png 300w, https:\/\/appliedex.com\/wp-content\/uploads\/2024\/11\/1731810850438-768x291.png 768w, https:\/\/appliedex.com\/wp-content\/uploads\/2024\/11\/1731810850438-18x7.png 18w, https:\/\/appliedex.com\/wp-content\/uploads\/2024\/11\/1731810850438.png 1452w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Graphique de la temp\u00e9rature du b\u00e9ton et de l'air<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"ember894\">Comprendre les diff\u00e9rents syst\u00e8mes de rev\u00eatement de sol<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"ember895\">Chaque syst\u00e8me de rev\u00eatement de sol r\u00e9sineux r\u00e9agit diff\u00e9remment aux facteurs de temp\u00e9rature et environnementaux :<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"ember896\">1. Rev\u00eatements \u00e9poxy<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Temp\u00e9rature du substrat :<\/strong> 10\u00b0C \u00e0 30\u00b0C (50\u00b0F \u00e0 86\u00b0F)<\/li>\n\n\n\n<li><strong>Contr\u00f4le de l'humidit\u00e9 :<\/strong> Maintenez l&#x27;humidit\u00e9 relative en dessous de 85 % pendant l&#x27;application.<\/li>\n\n\n\n<li><strong>Risques cl\u00e9s :<\/strong> La condensation en dessous du point de ros\u00e9e provoque des probl\u00e8mes d'adh\u00e9rence et des finitions voil\u00e9es.<\/li>\n\n\n\n<li><strong>Impact de la clim :<\/strong> Le refroidissement direct peut cr\u00e9er de la condensation et des d\u00e9fauts de surface.<\/li>\n\n\n\n<li><strong>Meilleure pratique :<\/strong> Maintenir la temp\u00e9rature du substrat \u00e0 au moins <strong>3\u00b0C (5\u00b0F)<\/strong> au-dessus du point de ros\u00e9e.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"ember898\">2. Ciment ur\u00e9thane (CU)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Temp\u00e9rature du substrat :<\/strong> 5\u00b0C \u00e0 30\u00b0C (41\u00b0F \u00e0 86\u00b0F)<\/li>\n\n\n\n<li><strong>Risques cl\u00e9s :<\/strong> Les basses temp\u00e9ratures ralentissent la prise ; les hautes temp\u00e9ratures l'acc\u00e9l\u00e8rent, r\u00e9duisant la maniabilit\u00e9.<\/li>\n\n\n\n<li><strong>Impact de la clim :<\/strong> Le refroidissement rapide peut perturber le durcissement dans les espaces \u00e0 forte humidit\u00e9.<\/li>\n\n\n\n<li><strong>Meilleure pratique :<\/strong> Utilisez des radiateurs ou des d\u00e9shumidificateurs pour maintenir des conditions stables.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"ember900\">3. Rev\u00eatements Polyaspartiques<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Temp\u00e9rature du substrat :<\/strong> 10\u00b0C \u00e0 30\u00b0C (50\u00b0F \u00e0 86\u00b0F)<\/li>\n\n\n\n<li><strong>Risques cl\u00e9s :<\/strong> Un durcissement rapide \u00e0 des temp\u00e9ratures \u00e9lev\u00e9es peut entra\u00eener des r\u00e9sultats in\u00e9gaux.<\/li>\n\n\n\n<li><strong>Impact de la clim :<\/strong> Les courants d&#x27;air peuvent acc\u00e9l\u00e9rer ou retarder le durcissement de mani\u00e8re irr\u00e9guli\u00e8re.<\/li>\n\n\n\n<li><strong>Meilleure pratique :<\/strong> \u00c9viter l'installation sous un flux d'air direct provenant des bouches d'a\u00e9ration.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"ember902\">4. M\u00e9thacrylate de m\u00e9thyle (MMA)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Temp\u00e9rature du substrat :<\/strong> -20\u00b0C \u00e0 30\u00b0C<\/li>\n\n\n\n<li><strong>Risques cl\u00e9s :<\/strong> Le MMA fonctionne bien dans des conditions froides mais peut \u00eatre affect\u00e9 par l'humidit\u00e9.<\/li>\n\n\n\n<li><strong>Impact de la clim :<\/strong> Pas critique dans des conditions froides mais peut introduire de la condensation dans des zones chaudes.<\/li>\n\n\n\n<li><strong>Meilleure pratique :<\/strong> Pr\u00e9parer les mat\u00e9riaux et assurer une bonne ventilation.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"ember904\">Pourquoi le point de ros\u00e9e et l'humidit\u00e9 sont importants<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"ember905\">La <strong>point de ros\u00e9e<\/strong> la temp\u00e9rature \u00e0 laquelle l'humidit\u00e9 se condense sur les surfaces. Si la temp\u00e9rature du substrat tombe en dessous du point de ros\u00e9e, une condensation peut se produire, provoquant :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Mauvaise adh\u00e9rence<\/li>\n\n\n\n<li>Bulles de surface ou crat\u00e8res<\/li>\n\n\n\n<li>Finition nuageuse ou in\u00e9gale<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"ember907\"><strong>Meilleure pratique :<\/strong> Lors de l'installation, assure <strong>3\u00b0C (5\u00b0F)<\/strong> au-dessus du point de ros\u00e9e.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"702\" height=\"676\" src=\"https:\/\/appliedex.com\/wp-content\/uploads\/2024\/11\/1731813911068.jpg\" alt=\"Tableau de temp\u00e9rature de l&#039;air \u00e0 humidit\u00e9 relative\" class=\"wp-image-10998\" srcset=\"https:\/\/appliedex.com\/wp-content\/uploads\/2024\/11\/1731813911068.jpg 702w, https:\/\/appliedex.com\/wp-content\/uploads\/2024\/11\/1731813911068-300x289.jpg 300w, https:\/\/appliedex.com\/wp-content\/uploads\/2024\/11\/1731813911068-12x12.jpg 12w\" sizes=\"(max-width: 702px) 100vw, 702px\" \/><figcaption class=\"wp-element-caption\">Tableau de temp\u00e9rature de l'air \u00e0 humidit\u00e9 relative<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"ember909\">Lorsque la temp\u00e9rature de l'air est <strong>23,9\u00b0C,<\/strong> et l'humidit\u00e9 relative de la pi\u00e8ce est <strong>35%<\/strong>, le <strong>point de ros\u00e9e<\/strong> est calcul\u00e9 \u00e0 <strong>45\u00b0F<\/strong>. Cela signifie que si la temp\u00e9rature de votre sol descend \u00e0 <strong>45\u00b0F ou moins<\/strong>, le rev\u00eatement du sol devient risqu\u00e9. La plupart des fiches techniques recommandent d'\u00e9viter le rev\u00eatement du sol dans <strong>-15\u00b0C<\/strong> du point de ros\u00e9e pour \u00e9viter des probl\u00e8mes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"ember910\">Pourquoi ? Au point de ros\u00e9e ou en dessous, <strong>de l'humidit\u00e9 condens\u00e9e peut se former sur la surface de la dalle de b\u00e9ton<\/strong>, ce qui entra\u00eene des probl\u00e8mes tels qu&#x27;une mauvaise adh\u00e9rence, un durcissement insuffisant et une alt\u00e9ration de l&#x27;int\u00e9grit\u00e9 du film de rev\u00eatement.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"ember911\">De plus, il est essentiel de comprendre la relation entre <strong>humidit\u00e9 relative (HR)<\/strong> et le point de ros\u00e9e. \u00c0 <strong>100% RH<\/strong>, le point de ros\u00e9e est \u00e9gal \u00e0 la temp\u00e9rature de l'air. En effet, \u00e0 saturation compl\u00e8te, l'air ne peut plus contenir d'humidit\u00e9 suppl\u00e9mentaire. Par exemple, \u00e0 <strong>100% RH<\/strong> et <strong>29,4\u00b0C<\/strong>, un chiffon humide plac\u00e9 \u00e0 l'ext\u00e9rieur ne s\u00e8chera pas. L'air est d\u00e9j\u00e0 satur\u00e9, ne laissant aucune possibilit\u00e9 \u00e0 l'humidit\u00e9 du chiffon de s'\u00e9vaporer.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"ember912\">Comprendre ces concepts est essentiel pour garantir la r\u00e9ussite des applications de rev\u00eatement de sol et \u00e9viter des erreurs co\u00fbteuses caus\u00e9es par les conditions environnementales.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"ember913\">Gestion des syst\u00e8mes de climatisation et CVCA<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Risques de la CA :<\/strong> Un flux d'air direct peut entra\u00eener un refroidissement in\u00e9gal, de la condensation ou une contamination.<\/li>\n\n\n\n<li><strong>Meilleure pratique :<\/strong> D\u00e9tourner les bouches d'a\u00e9ration ou \u00e9teindre les syst\u00e8mes CVC dans les zones critiques pendant l'application.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"ember915\">Meilleures pratiques pour l'installation de rev\u00eatements de sol en r\u00e9sine<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Mesurer les temp\u00e9ratures avec pr\u00e9cision :<\/strong> Utilisez des thermom\u00e8tres infrarouges pour le b\u00e9ton et des hygrom\u00e8tres pour l'air.<\/li>\n\n\n\n<li><strong>Stabiliser l'environnement<\/strong> Utilisez des chauffages, des d\u00e9shumidificateurs ou des ventilateurs pour maintenir des conditions id\u00e9ales.<\/li>\n\n\n\n<li><strong>Planification des changements saisonniers :<\/strong> Surveillez la temp\u00e9rature et l'humidit\u00e9 tout au long de la journ\u00e9e de travail.<\/li>\n\n\n\n<li><strong>Mesures de logs :<\/strong> Tenez des registres d\u00e9taill\u00e9s pour assurer la conformit\u00e9 aux sp\u00e9cifications du fabricant.<\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"380\" src=\"https:\/\/appliedex.com\/wp-content\/uploads\/2024\/11\/1731814336010.png\" alt=\"Rouleau d&#039;application sur \u00e9poxy\" class=\"wp-image-11000\" srcset=\"https:\/\/appliedex.com\/wp-content\/uploads\/2024\/11\/1731814336010.png 500w, https:\/\/appliedex.com\/wp-content\/uploads\/2024\/11\/1731814336010-300x228.png 300w, https:\/\/appliedex.com\/wp-content\/uploads\/2024\/11\/1731814336010-16x12.png 16w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><figcaption class=\"wp-element-caption\">Rouleau d'application sur \u00e9poxy<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"ember918\">Points cl\u00e9s \u00e0 retenir<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Le contr\u00f4le de la temp\u00e9rature, de l'humidit\u00e9 et du point de ros\u00e9e est essentiel pour des installations impeccables.<\/li>\n\n\n\n<li>Chaque syst\u00e8me de r\u00e9sine (\u00e9poxy, ciment polyur\u00e9thane, polyaspartique et MMA) a des exigences environnementales sp\u00e9cifiques.<\/li>\n\n\n\n<li>Une mesure pr\u00e9cise et une gestion environnementale appropri\u00e9e pr\u00e9viennent les erreurs co\u00fbteuses.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"ember920\">Besoin d'aide experte pour votre projet de rev\u00eatement de sol en r\u00e9sine ? Contactez-nous d\u00e8s aujourd'hui pour des conseils professionnels et une installation impeccable !<\/p>","protected":false},"excerpt":{"rendered":"<p>The Importance of Environmental Conditions in Resinous Flooring Installations \ud83c\udf21\ufe0f\ud83d\udca7 Proper control of temperature, dew point, and environmental conditions is essential for successfully installing epoxy coatings, polyurethane cement, polyaspartic, and MMA flooring systems. Mismanagement can lead to failures like poor adhesion, bubbling, or inconsistent curing. In this guide, we\u2019ll cover: Measuring Concrete and Air Temperature [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":10992,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[11],"tags":[],"class_list":["post-10991","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-quality-assurance"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.6 (Yoast SEO v28.6) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Environmental Conditions in Resinous Flooring - AppliedeX<\/title>\n<meta name=\"description\" content=\"Discover the importance of managing environmental conditions for resinous flooring installation. Avoid failures and achieve optimal results.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/appliedex.com\/fr\/blog\/temperature-point-de-rosee-et-conditions-environnementales-dans-les-installations-de-revetements-de-sol-en-resine\/\" \/>\n<meta property=\"og:locale\" content=\"fr_CA\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"%title% | AppliedeX Industrial Flooring &amp; Ultraflat Grinding\" \/>\n<meta property=\"og:description\" content=\"Learn about industrial flooring, coatings, concrete repair, and ultraflat grinding from the experts at AppliedeX. Practical insights, real\u2011world solutions, and proven industry knowledge.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/appliedex.com\/fr\/blog\/temperature-point-de-rosee-et-conditions-environnementales-dans-les-installations-de-revetements-de-sol-en-resine\/\" \/>\n<meta property=\"og:site_name\" content=\"AppliedeX\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/appliedfloors\/\" \/>\n<meta property=\"article:published_time\" content=\"2024-11-18T15:44:51+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/appliedex.com\/wp-content\/uploads\/2024\/11\/1731811485517.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"AppliedeX\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"AppliedeX\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimation du temps de lecture\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/appliedex.com\\\/blog\\\/temperature-dew-point-and-environmental-conditions-in-resinous-flooring-installations\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/appliedex.com\\\/blog\\\/temperature-dew-point-and-environmental-conditions-in-resinous-flooring-installations\\\/\"},\"author\":{\"name\":\"AppliedeX\",\"@id\":\"https:\\\/\\\/appliedex.com\\\/#\\\/schema\\\/person\\\/25204532c629a9f0872360d49502112f\"},\"headline\":\"Temperature, Dew Point, and Environmental Conditions in Resinous Flooring Installations\",\"datePublished\":\"2024-11-18T15:44:51+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/appliedex.com\\\/blog\\\/temperature-dew-point-and-environmental-conditions-in-resinous-flooring-installations\\\/\"},\"wordCount\":785,\"publisher\":{\"@id\":\"https:\\\/\\\/appliedex.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/appliedex.com\\\/blog\\\/temperature-dew-point-and-environmental-conditions-in-resinous-flooring-installations\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/appliedex.com\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/1731811485517.png\",\"articleSection\":[\"Quality Assurance\"],\"inLanguage\":\"fr-CA\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/appliedex.com\\\/blog\\\/temperature-dew-point-and-environmental-conditions-in-resinous-flooring-installations\\\/\",\"url\":\"https:\\\/\\\/appliedex.com\\\/blog\\\/temperature-dew-point-and-environmental-conditions-in-resinous-flooring-installations\\\/\",\"name\":\"Environmental Conditions in Resinous Flooring - AppliedeX\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/appliedex.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/appliedex.com\\\/blog\\\/temperature-dew-point-and-environmental-conditions-in-resinous-flooring-installations\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/appliedex.com\\\/blog\\\/temperature-dew-point-and-environmental-conditions-in-resinous-flooring-installations\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/appliedex.com\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/1731811485517.png\",\"datePublished\":\"2024-11-18T15:44:51+00:00\",\"description\":\"Discover the importance of managing environmental conditions for resinous flooring installation. Avoid failures and achieve optimal results.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/appliedex.com\\\/blog\\\/temperature-dew-point-and-environmental-conditions-in-resinous-flooring-installations\\\/#breadcrumb\"},\"inLanguage\":\"fr-CA\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/appliedex.com\\\/blog\\\/temperature-dew-point-and-environmental-conditions-in-resinous-flooring-installations\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-CA\",\"@id\":\"https:\\\/\\\/appliedex.com\\\/blog\\\/temperature-dew-point-and-environmental-conditions-in-resinous-flooring-installations\\\/#primaryimage\",\"url\":\"https:\\\/\\\/appliedex.com\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/1731811485517.png\",\"contentUrl\":\"https:\\\/\\\/appliedex.com\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/1731811485517.png\",\"width\":1280,\"height\":720,\"caption\":\"Resinous Flooring Installations\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/appliedex.com\\\/blog\\\/temperature-dew-point-and-environmental-conditions-in-resinous-flooring-installations\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/appliedex.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Temperature, Dew Point, and Environmental Conditions in Resinous Flooring Installations\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/appliedex.com\\\/#website\",\"url\":\"https:\\\/\\\/appliedex.com\\\/\",\"name\":\"AppliedeX\",\"description\":\"The Future of Flooring for Automation\",\"publisher\":{\"@id\":\"https:\\\/\\\/appliedex.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/appliedex.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-CA\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/appliedex.com\\\/#organization\",\"name\":\"AppliedeX\",\"url\":\"https:\\\/\\\/appliedex.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-CA\",\"@id\":\"https:\\\/\\\/appliedex.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/appliedex.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/Logo_AppliedeX_B_Crop-scaled-2.png\",\"contentUrl\":\"https:\\\/\\\/appliedex.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/Logo_AppliedeX_B_Crop-scaled-2.png\",\"width\":2560,\"height\":585,\"caption\":\"AppliedeX\"},\"image\":{\"@id\":\"https:\\\/\\\/appliedex.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/appliedfloors\\\/\",\"https:\\\/\\\/www.instagram.com\\\/appliedindustrialflooring\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/applied-industrial-flooring-canada\\\/\"],\"description\":\"AppliedeX is a leading provider of industrial flooring, concrete repair, protective coatings, and ultraflat floor grinding solutions. We help warehouses, manufacturers, and commercial facilities improve safety, durability, and operational performance through precision\u2011engineered flooring systems and expert installation.\",\"email\":\"info@appliedex.com\",\"telephone\":\"1-(800) 824-2443\",\"legalName\":\"AppliedeX\",\"foundingDate\":\"1975-01-24\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"51\",\"maxValue\":\"200\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/appliedex.com\\\/#\\\/schema\\\/person\\\/25204532c629a9f0872360d49502112f\",\"name\":\"AppliedeX\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-CA\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7fb0842a296499f042126f0834086b6f640deb0852afb0126f65399a838ad13c?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7fb0842a296499f042126f0834086b6f640deb0852afb0126f65399a838ad13c?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7fb0842a296499f042126f0834086b6f640deb0852afb0126f65399a838ad13c?s=96&d=mm&r=g\",\"caption\":\"AppliedeX\"},\"url\":\"https:\\\/\\\/appliedex.com\\\/fr\\\/blog\\\/author\\\/appliedex\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Conditions environnementales dans les rev\u00eatements de sol r\u00e9sineux - AppliedeX","description":"D\u00e9couvrez l'importance de g\u00e9rer les conditions environnementales pour l'installation de sols en r\u00e9sine. \u00c9vitez les \u00e9checs et obtenez des r\u00e9sultats optimaux.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/appliedex.com\/fr\/blog\/temperature-point-de-rosee-et-conditions-environnementales-dans-les-installations-de-revetements-de-sol-en-resine\/","og_locale":"fr_CA","og_type":"article","og_title":"%title% | AppliedeX Industrial Flooring & Ultraflat Grinding","og_description":"Learn about industrial flooring, coatings, concrete repair, and ultraflat grinding from the experts at AppliedeX. Practical insights, real\u2011world solutions, and proven industry knowledge.","og_url":"https:\/\/appliedex.com\/fr\/blog\/temperature-point-de-rosee-et-conditions-environnementales-dans-les-installations-de-revetements-de-sol-en-resine\/","og_site_name":"AppliedeX","article_publisher":"https:\/\/www.facebook.com\/appliedfloors\/","article_published_time":"2024-11-18T15:44:51+00:00","og_image":[{"width":1280,"height":720,"url":"https:\/\/appliedex.com\/wp-content\/uploads\/2024\/11\/1731811485517.png","type":"image\/png"}],"author":"AppliedeX","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"AppliedeX","Estimation du temps de lecture":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/appliedex.com\/blog\/temperature-dew-point-and-environmental-conditions-in-resinous-flooring-installations\/#article","isPartOf":{"@id":"https:\/\/appliedex.com\/blog\/temperature-dew-point-and-environmental-conditions-in-resinous-flooring-installations\/"},"author":{"name":"AppliedeX","@id":"https:\/\/appliedex.com\/#\/schema\/person\/25204532c629a9f0872360d49502112f"},"headline":"Temperature, Dew Point, and Environmental Conditions in Resinous Flooring Installations","datePublished":"2024-11-18T15:44:51+00:00","mainEntityOfPage":{"@id":"https:\/\/appliedex.com\/blog\/temperature-dew-point-and-environmental-conditions-in-resinous-flooring-installations\/"},"wordCount":785,"publisher":{"@id":"https:\/\/appliedex.com\/#organization"},"image":{"@id":"https:\/\/appliedex.com\/blog\/temperature-dew-point-and-environmental-conditions-in-resinous-flooring-installations\/#primaryimage"},"thumbnailUrl":"https:\/\/appliedex.com\/wp-content\/uploads\/2024\/11\/1731811485517.png","articleSection":["Quality Assurance"],"inLanguage":"fr-CA"},{"@type":"WebPage","@id":"https:\/\/appliedex.com\/blog\/temperature-dew-point-and-environmental-conditions-in-resinous-flooring-installations\/","url":"https:\/\/appliedex.com\/blog\/temperature-dew-point-and-environmental-conditions-in-resinous-flooring-installations\/","name":"Conditions environnementales dans les rev\u00eatements de sol r\u00e9sineux - AppliedeX","isPartOf":{"@id":"https:\/\/appliedex.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/appliedex.com\/blog\/temperature-dew-point-and-environmental-conditions-in-resinous-flooring-installations\/#primaryimage"},"image":{"@id":"https:\/\/appliedex.com\/blog\/temperature-dew-point-and-environmental-conditions-in-resinous-flooring-installations\/#primaryimage"},"thumbnailUrl":"https:\/\/appliedex.com\/wp-content\/uploads\/2024\/11\/1731811485517.png","datePublished":"2024-11-18T15:44:51+00:00","description":"D\u00e9couvrez l'importance de g\u00e9rer les conditions environnementales pour l'installation de sols en r\u00e9sine. \u00c9vitez les \u00e9checs et obtenez des r\u00e9sultats optimaux.","breadcrumb":{"@id":"https:\/\/appliedex.com\/blog\/temperature-dew-point-and-environmental-conditions-in-resinous-flooring-installations\/#breadcrumb"},"inLanguage":"fr-CA","potentialAction":[{"@type":"ReadAction","target":["https:\/\/appliedex.com\/blog\/temperature-dew-point-and-environmental-conditions-in-resinous-flooring-installations\/"]}]},{"@type":"ImageObject","inLanguage":"fr-CA","@id":"https:\/\/appliedex.com\/blog\/temperature-dew-point-and-environmental-conditions-in-resinous-flooring-installations\/#primaryimage","url":"https:\/\/appliedex.com\/wp-content\/uploads\/2024\/11\/1731811485517.png","contentUrl":"https:\/\/appliedex.com\/wp-content\/uploads\/2024\/11\/1731811485517.png","width":1280,"height":720,"caption":"Resinous Flooring Installations"},{"@type":"BreadcrumbList","@id":"https:\/\/appliedex.com\/blog\/temperature-dew-point-and-environmental-conditions-in-resinous-flooring-installations\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/appliedex.com\/"},{"@type":"ListItem","position":2,"name":"Temperature, Dew Point, and Environmental Conditions in Resinous Flooring Installations"}]},{"@type":"WebSite","@id":"https:\/\/appliedex.com\/#website","url":"https:\/\/appliedex.com\/","name":"AppliedeX","description":"L'avenir des sols pour l'automatisation","publisher":{"@id":"https:\/\/appliedex.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/appliedex.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-CA"},{"@type":"Organization","@id":"https:\/\/appliedex.com\/#organization","name":"AppliedeX","url":"https:\/\/appliedex.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-CA","@id":"https:\/\/appliedex.com\/#\/schema\/logo\/image\/","url":"https:\/\/appliedex.com\/wp-content\/uploads\/2026\/04\/Logo_AppliedeX_B_Crop-scaled-2.png","contentUrl":"https:\/\/appliedex.com\/wp-content\/uploads\/2026\/04\/Logo_AppliedeX_B_Crop-scaled-2.png","width":2560,"height":585,"caption":"AppliedeX"},"image":{"@id":"https:\/\/appliedex.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/appliedfloors\/","https:\/\/www.instagram.com\/appliedindustrialflooring\/","https:\/\/www.linkedin.com\/company\/applied-industrial-flooring-canada\/"],"description":"AppliedeX est un fournisseur de premier plan de solutions pour les rev\u00eatements de sol industriels, la r\u00e9paration du b\u00e9ton, les rev\u00eatements protecteurs et le meulage de sols ultra-plats. Nous aidons les entrep\u00f4ts, les fabricants et les installations commerciales \u00e0 am\u00e9liorer la s\u00e9curit\u00e9, la durabilit\u00e9 et les performances op\u00e9rationnelles gr\u00e2ce \u00e0 des syst\u00e8mes de rev\u00eatement de sol con\u00e7us avec pr\u00e9cision et \u00e0 une installation experte.","email":"info@appliedex.com","telephone":"1-(800) 824-2443","legalName":"AppliedeX","foundingDate":"1975-01-24","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"51","maxValue":"200"}},{"@type":"Person","@id":"https:\/\/appliedex.com\/#\/schema\/person\/25204532c629a9f0872360d49502112f","name":"AppliedeX","image":{"@type":"ImageObject","inLanguage":"fr-CA","@id":"https:\/\/secure.gravatar.com\/avatar\/7fb0842a296499f042126f0834086b6f640deb0852afb0126f65399a838ad13c?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/7fb0842a296499f042126f0834086b6f640deb0852afb0126f65399a838ad13c?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/7fb0842a296499f042126f0834086b6f640deb0852afb0126f65399a838ad13c?s=96&d=mm&r=g","caption":"AppliedeX"},"url":"https:\/\/appliedex.com\/fr\/blog\/author\/appliedex\/"}]}},"_links":{"self":[{"href":"https:\/\/appliedex.com\/fr\/wp-json\/wp\/v2\/posts\/10991","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/appliedex.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/appliedex.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/appliedex.com\/fr\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/appliedex.com\/fr\/wp-json\/wp\/v2\/comments?post=10991"}],"version-history":[{"count":0,"href":"https:\/\/appliedex.com\/fr\/wp-json\/wp\/v2\/posts\/10991\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/appliedex.com\/fr\/wp-json\/wp\/v2\/media\/10992"}],"wp:attachment":[{"href":"https:\/\/appliedex.com\/fr\/wp-json\/wp\/v2\/media?parent=10991"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/appliedex.com\/fr\/wp-json\/wp\/v2\/categories?post=10991"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/appliedex.com\/fr\/wp-json\/wp\/v2\/tags?post=10991"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}